Filter Results By:

Products

Applications

Manufacturers

Showing results: 466 - 480 of 672 items found.

  • AC Power Source

    AFC series - Preen AC Power Corp.

    The AFC Series is an economically priced AC power source to provide reliable voltage and frequency simulation for general applications, such as testing for home appliance, electronic, medical equipment, lighting and other fields of production or R&D. Utilized PWM switching technology, AFC provides high quality pure sine waveform with output level up to 2,000kVA. The AC source is coupled with output voltage range of 5~300V and output frequency of 47~63Hz, 50/60Hz fixed. User can select optional frequency output of 2 or 4 times standard frequency and 400Hz.

  • Wound Component EST Analyzer

    19036 - Chroma Systems Solutions, Inc.

    The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.

  • Cable Tester

    Finero OY

    FST-500 High Voltage Cable Tester is a modular and customizable cable tester that can be easily adapted to various cable test or cable harness test applications. The electronics is based on Finero’s rugged industrial grade FST range of standard test equipment. All set and measured values are shown on alphanumeric display, additionally there is an analog panel meter for output voltage. Other cable paramerter like L, C and R can also be tested by using optional test and measurement equipment. The tester can be ordered with a build in PC and it can be used in conjunction with Finero’s Quality Control software.

  • Dry Arc Resistance Tester

    SCR ELEKTRONIKS

    Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to decomposition and erosion.AdvantagesThis Test ensures that your products meet high standards of quality & safety. This product is meant for all Switchgears/ insulator/ Polymer/ electro plastic manufacturers and manufacturers who use insulators in their products e.g. Wiring Accessories, Appliances, HT/LT line insulators etc.

  • Rail-to-Rail Op Amplifiers

    Analog Devices Inc.

    Analog Devices high speed (> 50 MHz) rail-to-rail op amps enable you to operate at lower supply voltages, swing closer to the rails, and provide wider dynamic range. Featuring a portfolio with a wide variety of op amps, including both rail-to-rail input/output as well as just rail-to-rail output, ADI provides the widest portfolio of leading edge products available on the market. Whether it is wide bandwidth, high slew rate or low distortion, or rail to rail, no one sets more performance standards for next generation designs than Analog Devices.

  • Power Monitor

    Extech PM120 - Extech Instruments Corporation

    Monitor and record power usage of home and work appliances for energy conservation and cost reduction analysis with the Extech PM120 Power Monitor. This helps you determine if the electrical device should be replaced with a higher efficiency unit. The PM120 has a large dual LCD. The primary display shows voltage, current, power, power factor, and frequency readings. The secondary display shows total time, cost (cost of operation per minute, day, or week), set, or energy. Design includes a standard, North American 3 prong plug, front socket connection, and backup battery that saves customized programs.

  • Voltage Testers

    DUSPOL - BENNING Elektrotechnik und Elektronik GmbH

    phase-sequence test (counter-clockwise / clockwise)single-pole phase test: " symbol (red LED)measuring point illuminationacoustic and optical continuity testfrequency measurement 1 1000 Hzvoltage indication 1 1000 V AC TRUE RMS / 1200 V DCresistance measurement and diode test with conducting-state voltage indicationlc display with background lightingsensor of non-contact cable break detectorload connection via large-scale push buttonsvibrating alert in the test handleshock-resistant housing with protection against dust and water jets (protection class IP 65) and rubberized test handleDIN EN 61243-3 (VDE 0682-401): 2015 standard

  • Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.

    72-2985 - Tenma

    The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.

  • Digital Power Meter

    66205 - Chroma ATE Inc.

    The 66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state of art design is capable of providing highly accurate power measurements to meet the requirements of IEC 62301/EN50564 standards. Functionality improvements of the 66205 increase power measurement capabilities to a wider range of applications. The Smart Range function is one of the most important new features added to the 66205 power meter. Smart Range allows the power integration mode to perform active power measurements with the measurement range in auto mode. Chroma’s proprietary design automatically selects the appropriate range, based on changes in sensed voltage and current, ensures the best accuracy when integrating the measurements over time. The 66205 provides 10 selectable current measurement ranges from 5mA up to 30A. External sensor options A662017~A662020 are available to increase the current measurement range. Six selectable voltage ranges are available up to 600V.

  • 3 Wire (Digital) Earth Resistance Tester

    1120 ER - Standard Electric Works Co., Ltd

    ● Waterproof: IP54● Capable of measuring earth resistance and earth voltage● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test● The test leads are supplied as standard accessories for simplified two-wire measuring system● 0Ω adjustment● Battery operated● Data hold function● Low battery indication

  • DC Power Supply

    62000H Series - Chroma ATE Inc.

    The 62000H Series includes 14 different models ranging from 5KW to 15KW, with current range up to 375A and voltage range up to 1000V. The 62000H can easily parallel up to ten units capable of 150KW with current sharing for bulk power applications, for example, battery bank simulation of 450V/150A/67.5KW for electric vehicle and military use. There are 100 user programmable input status on the front panel for automated test application and life cycle ON/OFF test. In addition, the 62000H has a 16 bit digital control with bright vacuum fluorescent display readout. The 62000H series DC power supplies are very easy to operate either from the front panel keypad or from the remote controller via USB / RS232 / RS485 / APG (Standard) and GPIB & Ethernet (optional). Its compact size with 3U only can be stacked on a bench in a standard rack without any difficulty.

  • Impulse Winding Tester

    TH2883-1 - Changzhou Tonghui Electronic Co., Ltd.

    TH2883 series products are newly developed impulse winding testers by Tonghui. This product line makes Tonghui as the first provider of impulse winding tester from low voltage of 30V to high voltage of 10kV, single channel to multichannel (Max.:8 channels) in this industry. The instrument adopts popular 32 bit CPU and high density SMD technology, 65k color 7-inch TFT wide display screen, bringing ease for your eyes and convenience to your operation. The minimum impulse voltage of 30V, maximum impulse voltage output of 10kV, winding test of 1uH inductance value, sampling rate of 200Msps, memory depth of 6k bytes makes your test accurately. The usage of standard sample average, application of demagnetized impulse, high bandwidth analog acquisition circuit, technology of high-fidelity corona extraction as well as the opening of non-destructive test reflect the design philosophy “customer-oriented, share the future technology with you” of Tonghui.

  • Impulse Winding Tester

    TH2883-5 - Changzhou Tonghui Electronic Co., Ltd.

    TH2883 series products are newly developed impulse winding testers by Tonghui. This product line makes Tonghui as the first provider of impulse winding tester from low voltage of 30V to high voltage of 10kV, single channel to multichannel (Max.:8 channels) in this industry. The instrument adopts popular 32 bit CPU and high density SMD technology, 65k color 7-inch TFT wide display screen, bringing ease for your eyes and convenience to your operation. The minimum impulse voltage of 30V, maximum impulse voltage output of 10kV, winding test of 1uH inductance value, sampling rate of 200Msps, memory depth of 6k bytes makes your test accurately. The usage of standard sample average, application of demagnetized impulse, high bandwidth analog acquisition circuit, technology of high-fidelity corona extraction as well as the opening of non-destructive test reflect the design philosophy “customer-oriented, share the future technology with you” of Tonghui.

  • Impulse Winding Tester

    TH2883-10 - Changzhou Tonghui Electronic Co., Ltd.

    TH2883 series products are newly developed impulse winding testers by Tonghui. This product line makes Tonghui as the first provider of impulse winding tester from low voltage of 30V to high voltage of 10kV, single channel to multichannel (Max.:8 channels) in this industry. The instrument adopts popular 32 bit CPU and high density SMD technology, 65k color 7-inch TFT wide display screen, bringing ease for your eyes and convenience to your operation. The minimum impulse voltage of 30V, maximum impulse voltage output of 10kV, winding test of 1uH inductance value, sampling rate of 200Msps, memory depth of 6k bytes makes your test accurately. The usage of standard sample average, application of demagnetized impulse, high bandwidth analog acquisition circuit, technology of high-fidelity corona extraction as well as the opening of non-destructive test reflect the design philosophy “customer-oriented, share the future technology with you” of Tonghui.

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

Get Help